May 23, 2023

Public workspaceRetro-orbital injection of AAV in mice

  • 1California Institute of Technology
Icon indicating open access to content
QR code linking to this content
Protocol CitationMiguel Chuapoco 2023. Retro-orbital injection of AAV in mice. protocols.io https://dx.doi.org/10.17504/protocols.io.3byl4joy8lo5/v1
License: This is an open access protocol distributed under the terms of the Creative Commons Attribution License,  which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Protocol status: Working
We use this protocol and it's working
Created: May 09, 2023
Last Modified: May 31, 2024
Protocol Integer ID: 81665
Keywords: Mice, Retro-orbital injections, ASAPCRN
Abstract
This protocol is following:

CITATION
Tal Yardeni, Michael Eckhaus, H. Douglas Morris, Marjan Huizing, Shelley Hoogstraten-Miller (2011). Retro-orbital injections in mice. LabAnimal.





Guidelines
Please adhere to your institue IACUC guidelines of animal care.
Materials
MATERIALS
Reagent29G x 12.7mm 0.3ml syringeUlticareCatalog #09230
STEP MATERIALS
Reagent29G x 12.7mm 0.3ml syringeUlticareCatalog #09230
It is important that the needel used has low friction so that the injection is at a slow and consisitnat rate.
Injection
Injection
Prepare either virus dilution with PBS prepare. Injection is up to 100 μL per mouse.



Take one mouse from the cage into an induction chamber and start isoflurane at 3% with flow rate of ~1L/min
After the mouse has slow breathing (~1/s) move the mouse to a nose cone delivery of isoflurane at 1.5% with around the same flow rate.
Expose the eye ball with two fingers (above and below) and make sure the you are not pressing on the trachea and the mouse's breathing is regular.
Critical
Use a 31 G insulin syringe at a 30-degree angle beveled downwards until you hit the bone, retract a bit and slowly inject. See cited paper for more details.
CITATION
Tal Yardeni, Michael Eckhaus, H. Douglas Morris, Marjan Huizing, Shelley Hoogstraten-Miller (2011). Retro-orbital injections in mice. LabAnimal.

Equipment
U-100 BD Ultra-Fine™ Short Insulin Syringes
NAME
Syringe and neecdle
TYPE
BD Medical
BRAND
BD328438
SKU
LINK


Critical
Remove the needle slowly and press the eyelid shut for a few seconds.
Prior to recovery, apply 1-2 drops 0.5% ophthalmic Proparacaine to the injected eye