Rizzardi Lab (Adapted from Schwer Lab- UCSF)
Add coverslips to 10cm culture dish
Add ~20 mL of 1 N HCl; swirl on orbital shaker for 2 h at RT.TemperatureRoom temperature

2h
Remove acid, rinse with 2 x 25 mL PBS until pH is at least 6.0.
Rinse 1 x 25 mL water.
Add ~20 mL of 70% EtOH; swirl on orbital shaker for 10 min, RT.TemperatureRoom temperature

10m
Remove ethanol, transfer coverslips to Whatman paper. Let dry in TC hood.
Sterilize coverslips before use
Option 1:
Transfer to glass beaker, cover with aluminum foil and autoclave (dry cycle, 30 min sterilization time)
Option 2:
Transfer to new sterile 10cm culture dish and turn on UV.  Leave in hood until ready for use.