Sep 20, 2024

Public workspaceNGS library preparation using Ovation RNA-Seq System V2 (M01206 v9) and Ovation Ultralow System V2 (M01437 v2) for animal tissue samples

Forked from a private protocol
  • 1Department of Microbiology, Immunology and Transplantation, Rega Institute, KU Leuven – University of Leuven, Leuven, Belgium;
  • 2Bioinformatics and Applied Genomics Unit, Department of Microbiology, Hellenic Pasteur Institute;
  • 3Department of Hygiene, Epidemiology and Medical Statistics, National and Kapodistrian University of Athens;
  • 4Ruijin Hospital, Shanghai Jiao Tong University School of Medicine
Icon indicating open access to content
QR code linking to this content
Protocol CitationIne Boonen, Magda Bletsa, Yiqiao Li, Philippe Lemey 2024. NGS library preparation using Ovation RNA-Seq System V2 (M01206 v9) and Ovation Ultralow System V2 (M01437 v2) for animal tissue samples. protocols.io https://dx.doi.org/10.17504/protocols.io.14egn6w96l5d/v1
License: This is an open access protocol distributed under the terms of the Creative Commons Attribution License,  which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Protocol status: Working
We use this protocol and it's working
Created: July 02, 2024
Last Modified: September 20, 2024
Protocol Integer ID: 102727
Keywords: NGS, Library Preparation, Tissue samples, RNA Sequencing, Virus, Metagenomic
Abstract
This protocol is used for successful NGS library preparation from total RNA of animal tissue samples.
With this method we obtained full-length paramyxovirus genomes using the Illumina sequencing platform. It works most efficiently on RNA viruses possessing a polyA tail, but it can also be used for sequencing any other RNA viral sequences originating from tissue samples.
Guidelines
  • Thaw components used in each step and immediately place them on ice. Always keep thawed reagents and reaction tubes on ice unless otherwise instructed. Do not thaw all reagents at once.
  • After thawing and mixing buffer mixes, if any precipitate is observed, re-dissolve the precipitate completely prior to use. You may gently warm the buffer mix for 2 minutes at room temperature followed by brief vortexing.
  • Keep enzyme mixes on ice after briefly spinning to collect the contents. Do not vortex enzyme mixes nor warm any enzyme or primer mixes.
  • When instructed to mix via pipetting, gently aspirate and dispense a volume that is at least half of the total volume of the reaction mix.
  • Use only fresh ethanol stocks to prepare the dilutions of ethanol washes throughout the purification protocols.
  • Return all reagents to their appropriate storage conditions promptly after use unless otherwise instructed.
  • Total RNA input must be between 500 pg and 100 ng.
  • RNA samples must be free of contaminating proteins and other cellular material, organic solvents (including phenol and ethanol) and salts used in many RNA isolation methods. If a method such as Trizol is used, we recommend using a column purification after isolation.
Materials
Ovation RNA-Seq System V2 (M01206 v9)
ReagentMinElute Reaction Cleanup KitQiagenCatalog #28204 ReagentOvation® Ultralow V2 DNA-Seq Library Preparation KitTecanCatalog # 0344NB-A01

Protocol materials
ReagentMinElute Reaction Cleanup KitQiagenCatalog #28204
Step 44
ReagentOvation® Ultralow V2 DNA-Seq Library Preparation KitTecanCatalog # 0344NB-A01
Step 65
Safety warnings
Due to the high sensitivity inherent in this amplification system, we strongly recommend taking measures to minimize the potential for the carryover of previously amplified SPIA cDNA into new amplification reactions. The two steps to accomplish this are:
1. Designating separate workspaces for “pre-amplification” and “post-amplification” steps and materials.
2. Implementing routine clean-up protocols for workspaces as standard operating procedures.
Before start
  • Check RNA sample quality prior to library preparation. RNA sample quality may vary between sample preparations.
  • Ensure pipettes are properly calibrated as library preparations are highly sensitive to pipetting error.
A. Sample Preparation for Ovation RNA-Seq system V2
A. Sample Preparation for Ovation RNA-Seq system V2
Remove Nuclease-free water (Green: D1) from the freezer and let it thaw at TemperatureRoom temperature .

OVATION RNA-SEQ SYSTEM V2
OVATION RNA-SEQ SYSTEM V2
The following kit was used to prepare cDNA from RNA prior to the library preparation step:
Ovation RNA-SEQ System V2 (M01206 v9)
A. Sample Preparation for Ovation RNA-Seq system V2
A. Sample Preparation for Ovation RNA-Seq system V2
Aliquot each total RNA input sample (500 pg-100 ng) into a 0.2 ml strip tube or a 96-well plate. Input volume can not exceed Amount5 µL .

Dilute the RNA with D1 to a final volume of Amount5 µL .

Note: Keep D1 at TemperatureRoom temperature for use in next sections

B. First Strand cDNA Synthesis
B. First Strand cDNA Synthesis
Remove the First Strand Primer Mix (blue: A1) and First Strand Buffer mix (Blue: A2) from the freezer. Let it thaw at TemperatureRoom temperature . Mix by vortexing, spin down and place on ice.

Remove First Strand Enzyme Mix (blue: A3) from the freezer, spin down and place on ice.
Add Amount2 µL of A1 to Amount5 µL of each input RNA for a total of Amount7 µL . Mix by pipetting 5 times, spin down and place on ice.

Place the tubes in a preheated thermal cycler programmed to run the Primer annealing program:



Remove the tubes from the thermal cycler and place on ice.
Once the Primer annealing (step 8) is complete, prepare a master mix of A2 and A3 as follows:

Mix well by pipetting 5 times, spin down and place on ice.
Add Amount3 µL of First Strand Master Mix to each sample tube for a total of Amount10 µL . Mix by pipetting 5 times, spin and place on ice.

Place the tubes in a preheated thermal cycler programmed to run the First Strand synthesis program:



Remove the tubes from the thermal cycler, spin to collect all droplets from the wall of the tubes and place them on ice.
C. Second strand cDNA Synthesis
C. Second strand cDNA Synthesis
Remove Agencourt beads from the fridge and place on the bench top to reach TemperatureRoom temperature for use in the next step. (At least Duration00:30:00 before section D)

30m
Remove the Second Strand Buffer Mix (Yellow: B1) from the freezer. Let it thaw at TemperatureRoom temperature . Mix by vortexing, spin down and place on ice.

Remove Second Strand Enzyme Mix (Yellow: B2) from the freezer, spin down and place on ice.
Prepare a master mix of B1 and B2 as follows:

Mix well by pipetting 5 times, spin down and place on ice.
Add Amount10 µL of Second Strand Master Mix to each sample tube for a total of Amount20 µL Mix well by pipetting 5 times, spin down and place on ice.

Place the tubes in a preheated thermal cycler programmed to run the Second Strand synthesis program:


Remove the tubes from the thermal cycler, spin to collect all droplets from the wall of the tubes and place them in a rack on the bench top.
D. cDNA Purification
D. cDNA Purification
Ensure the Agencourt beads have completely reached TemperatureRoom temperature before proceeding.

Prepare a 70% Ethanol wash solution

NOTE:It is critical this solution to be prepared fresh on the same day of the experiment from a recently opened stock container.
Measure both water and ethanol components carefully prior to mixing. Failure to do so can result in a higher than anticipated aqueous content, which may reduce amplification yield.

Resuspend the beads by vortexing. Ensure that the beads are fully resuspended before adding them to the sample. After resuspending DO NOT spin the beads
At TemperatureRoom temperature , add Amount32 µL (1.6 volumes) of Agencourt beads to each reaction and mix by gently pipetting up and down 10 times.

Incubate at TemperatureRoom temperature for Duration00:10:00

10m
Transfer tubes to the magnet and let them stand for Duration00:05:00 until the solution of the beads seems completely clear.

5m
Keeping the tubes on the magnet, add Amount200 µL of freshly prepared 70% ethanol and allow to stand for Duration00:00:30 .
NOTE: The beads should not disperse; instead, they will stay on the walls of the tubes. Significant loss of beads at this stage will impact cDNA yields, so ensure beads are not removed with the binding buffer or the washes.

30s
Remove the 70% ethanol wash using a pipette.
Repeat the previous washing steps two more times.
With the final wash, it is critical to remove as much of the ethanol as possible. Use at least 2 pipetting steps and allow excess ethanol to collect at the bottom of the tubes after removing most of the ethanol in the first pipetting step. Try to remove last bits of ethanol with a smaller pipette.
Air-dry the bead on the magnet for 15 - 20 min. Inspect each tube carefully to ensure that all the ethanol has evaporated.
IMPORTANT!: It is critical that all residual ethanol be removed prior to continuing with SPIA amplification.
Continue immediately to the SPIA Amplification protocol with the cDNA still bound to the dry beads.
E. SPIA Amplification
E. SPIA Amplification
Remove the SPIA Primer Mix (Red: C1) and the SPIA Buffer Mix (Red: C2) from the freezer. Let it thaw at TemperatureRoom temperature . Mix by vortexing, spin down and place on ice.

Remove SPIA Enzymer Mix (Red: C3) from the freezer, mix the contents by inverting gently 5 times without introducing bubbles. Spin down and place on ice.
Prepare the SPIA master mix by sequentially combining C2, C1 and C3 as follows:

NOTE: Make sure to add C3 last.
Add Amount40 µL of the SPIA Master Mix to each tube containing the double-stranded cDNA bound to the dried beads. Use a pipette set to Amount30 µL and mix thoroughly by pipetting at least 8-10 times. Attempt to get the majority of the beads in suspension and remove most of the beads from the tube walls.
NOTE: The beads may not form a perfectly uniform suspension, but this will not affect the reaction. The addition of SPIA master mix will elute the cDNA from the beads.

Place the tubes in a pre-warmed thermal cycler programmed to run the SPIA amplification program:



Remove the tubes from thermal cycler, spin to collect condensation and place on ice.
IMPORTANT!: At this point the tubes should be removed from the pre-amplification workspace. Carry out all remaining steps in a post-amplification workspace using dedicated post-amplification consumables and equipment. Take care to avoid the introduction of previously amplified cDNA into your pre-amplification workspace.
Transfer tubes to the magnet and let them stand for Duration00:05:00 to completely clear the solution of beads.

5m
Carefully transfer Amount40 µL of the cleared supernatant containg the SPIA cDNA to a fresh tube.

Continue immediatly with the Purification of SPIA cDNA protocol or store the reaction products at Temperature-20 °C .

Pause
F. Purification of SPIA cDNA
F. Purification of SPIA cDNA
For purification the ReagentMinElute Reaction Cleanup KitQiagenCatalog #28204 was used following the manufacturer’s guidelines. This kit was chosen due to its low elution.
IMPORTANT!:
- Buffer ERC is considered hazardous according to QIAGEN, and an SDS should be consulted.
- Add the appropriate amount of 100% ethanol to Buffer PE before use (see bottle label for volume). Failure to do so will result in low amplification yields.
- All centrifugation steps are carried out at maximum speed in a conventional tabletop microcentrifuge at TemperatureRoom temperature .

Add Amount300 µL of Buffer ERC from the QIAGEN kit into a clean, labeled 1.5 ml microcentrifuge tube.
Transfer the entire volume (Amount40 µL ) of the SPIA reaction to the 1.5 ml tube containing buffer ERC.
Vortex for 5s and then spin briefly.
Label a MinElute spin column and place it into a collection tube.
Load the sample/buffer mixture onto the column and centrifuge Duration00:01:00 at maximum speed.
1m
Place the column in a new collection tube and discard the old collection tube with the flow-through.
Add 750 µl of Buffer PE to the column and centrifuge for Duration00:01:00 at maximum speed.
1m
Place the column in a new collection tube and discard the old collection tube with the flow-through.
Centrifuge the column for an additional Duration00:02:00 at maximum speed to remove all residual buffer PE.
2m
Discard flow-through along with collection tube. Blot the column tip onto clean absorbent paper to remove any residual wash buffer from the tip of the column.
Place the column into a clean labeled 1.5 ml microcentrifuge tube. Add Amount22 µL of TemperatureRoom temperature 1x TE or Buffer EB to the center of each column.

Let the column stand for Duration00:01:00 at TemperatureRoom temperature .

1m
Centrifuge for Duration00:01:00 at maximum speed.

1m
Measure the volume recovered. There should be approximately 20 µl of purified SPIA cDNA. Then discard the column.
Continue with the SPIA cDNA yield and Purity Protocol or store the purified SPIA cDNA at Temperature-20 °C

Pause
G. SPIA cDNA Yield and Purity
G. SPIA cDNA Yield and Purity
Mix the purified SPIA cDNA sample by brief vortexing. Spin down contents.
Measure the absorbance at 230, 260, 280 and 320 nm on a spectophotometer. You may need to make a 1:20 dilution of the cDNA in water prior to measuring the absorbance.
Purity:
Subtract the A320 value from the A230, A260 and A280 values. The adjusted
(A260–A320) / (A280–A320) ratio should be greater than 1.8. The adjusted (A260–A320)/(A230–A320) ratio should be greater than 2.
Yield:
Assume 1 A260 unit = 50 μg/mL.
To calculate: (A260–A320 of diluted sample) X (dilution factor) X 50 (concentration in μg/mL of a 1 A260 unit solution) X 0.02 (final volume in mL) = total yield in micrograms
NOTE: If there is not available a spectrophotometer, you can use any other type of quantitation system to quantify the SPIA amplification products (i.e. Qubit, QuantiFluor).
The purified cDNA may be stored at Temperature-20 °C

Pause
OVATION ULTRALOW SYSTEM V2
OVATION ULTRALOW SYSTEM V2
The following kit was used to make libraries for sequencing from the previously prepared cDNA.
ReagentOvation® Ultralow V2 DNA-Seq Library Preparation KitTecanCatalog # 0344NB-A01
IMPORTANT!: Make sure to use reagents from the right kit. The reagents in the ovation RNA-seq system V2 product can be similar to reagents in this kit, however, unless the component part numbers are identical, these reagents do not have exactly the same composition and therefore, are not interchangeable. For example A1 from one kit with A1 from another kit.
NOTE: Remove Agencourt beads from fridge and Nuclease-free Water (green: D1) from freezer and place them on bench top.
H. DNA Fragmentation
H. DNA Fragmentation
No fragmentation step was performed, since the input cDNA fragment sizes were relatively short. Therefore, we also skipped the DNA purification step, which is normally performed after the DNA fragmentation, and directly proceeded to the end repair step.
I. End Repair
I. End Repair
Remove the End Repair Buffer Mix (Blue:ER1). Let it thaw at TemperatureRoom temperature . Mix by vortexing, spin down and place on ice.

Remove End Repair Enzyme Mix (Blue: ER2) and End Repair Enhancer (blue: ER3) from the freezer. Spin down and place on ice.
Obtain Amount10 µL of the cDNA sample (Amount10 pg Amount100 ng ) that was previously stored at Temperature-20 °C . Alternatively, place Amount10 pg Amount100 ng of DNA in Amount10 µL of low-EDTA TE buffer or Nuclease-free Water in a PCR tube.
Prepare the End repair master mix by combining ER1, ER2 and ER3 as follows:



Add Amount5 µL of the End Repair Master Mix to each sample tube and mix by pipetting. Spin the tubes down and place on ice.

Place the tubes in a preheated thermal cycler programmed to run the End Repair amplification program:



Remove the tubes from the thermal cycler, spin to collect all droplets from the wall of the tubes and place them on ice. Continue immediatly with the Ligation Protocol.
J. Ligation
J. Ligation
Remove the Ligation Buffer Mix (Yellow: L1) and Ligation Adaptor Mix (Yellow:L2) from the freezer. Let it thaw TemperatureOn ice . Mix by vortexing, spin down and place on ice.

Remove Ligation Enzyme Mix (Yellow:L3) from the freezer. Spin down and place on ice.
Add L2 to each sample as follows:
- If using adaptors from tubes (0344NB-08), add Amount6 µL of the appropriate L2 Ligation Adaptor Mix to each sample. Mix thoroughly by pipetting.
- If using an adaptor plate (0344-32, 0344NB-32 or 0344NB-A01), add the entire Amount15 µL of sample to the appropriate adaptor well, mix well by pipetting, then transfer the entire sample to a PCR tube.
NOTE: All samples on a sequencing run should have unique ligation adaptors.

Prepare the Ligation master mix by combining D1, L1 and L3 as follows:

NOTE: L1 is very viscous. Please be sure to pipette this reagent slowly.
Add Amount9 µL of the Ligation Master Mix to each sample tube and mix by pipetting. Spin the tubes down and place on ice. Proceed immediatly with the incubation.

Place the tubes in a preheated thermal cycler programmed to run the End Repair amplification program:



Remove the tubes from the thermal cycler, spin to collect all droplets from the wall of the tubes and place on ice. Continue immediately with the Ligation Purification Protocol.
K. Ligation Purification
K. Ligation Purification
Prepare a 70% ethanol wash solution. It is critical this solution to be prepared fresh on the same day of the experiment from a recently opened stock container. Measure both the ethanol and the water components carefully prior to mixing. Failure to do so can result in a higher than anticipated aqueous content, which may reduce yield.
Amount1.5 mL wash solution per sample is enough for all the bead purification steps.
Ensure the Agencourt beads and Nuclease-free Water (D1) have completely reached TemperatureRoom temperature before proceeding. Make sure beads are resuspended by inverting and tapping the tube. After resuspending, do not spin the beads.
Add Amount70 µL of TemperatureRoom temperature D1 to each ligation reaction.

At room temperature, add Amount80 µL (0.8 volumes) of the bead suspension to each tube and mix by pipetting 10 times.

Incubate at TemperatureRoom temperature for Duration00:10:00 .

10m
Transfer the PCR tubes containing the bead-sample mixture to the magnet and let them stand forDuration00:05:00 to completely clear the solution of beads.

Carefully remove Amount160 µL of the binding buffer and discard it. Leaving some of the volume behind minimizes bead loss at this step.

With the tubes still on the magnet, add Amount200 µL of freshly prepared 70% ethanol and allow to stand for Duration00:00:30 .

Remove the 70% ethanol wash using a pipette.
Repeat the 70% ethanol wash one more time, for a total of two washes.
With the final wash, it is critical to remove as much of the ethanol as possible. Use at least 2 pipetting steps and allow excess ethanol to collect at the bottom of the tubes after removing most of the ethanol in the first pipetting step. Try to remove last bits of ethanol with a smaller pipette.
Air dry the beads on the magnet for Duration00:10:00 . Inspect each tube carefully to ensure that all the ethanol has evaporated.

10m
Add Amount40 µL TemperatureRoom temperature 1X low-EDTA TE buffer or Nuclease-free Water (green: D1) to the dried beads. Mix thoroughly to ensure all the beads are resuspended and let them stand on the bench top for Duration00:03:00
3m
Transfer the tubes to the magnet and let them stand for Duration00:03:00 to completely clear the solution of beads.

3m
Carefully remove Amount35 µL of the eluate, ensuring as few beads as possible are carried over, then transfer to a fresh set of PCR tubes and place on ice.

Set aside the Agencourt beads and 70% ethanol at room temperature for use in the Amplified Library Purification protocol. Also set aside the Nuclease-free water (green:D1) for use throughout the protocol.
Continue immediately to the Library Amplification Protocol.
L. Library Amplification
L. Library Amplification
Remove the Amplification Buffer Mix (Red: P1), Amplification Primer Mix (Red: P2) from the freezer. Let it thaw at TemperatureRoom temperature . Mix by vortexing, spin down and place on ice.

Remove Amplification Enzyme Mix (Red: P3) from the freezer. Spin down and place on ice.
Prepare the Ligation master mix by sequentially combining P1 and P2. Add P3 last, as follows, and mix well, taking care to avoid bubbles. Then spin down and place on ice.



TemperatureOn ice Add Amount15 µL of the Amplification Master Mix to each sample tube and mix by pipetting. Spin the tubes down and place on ice.

Place the tubes in a preheated thermal cycler programmed to run the End Repair amplification program:


IMPORTANT!: The number of cycles used for PCR amplification depends on the starting amount of genomic DNA. Please refer to the table below for a general guide to choosing the appropriate number of cycles for the PCR amplification reaction. Alternatively, real-time PCR can be used to determine the appropriate number of PCR cycles.



Remove the tubes from the thermal cycler, spin to collect all droplets from the wall of the tubes and place on ice. Continue immediately with the Amplified Library Purification Protocol.
M. Amplified Library Purification
M. Amplified Library Purification
2m
2m
Take Agencourt beads and 70% ethanol that we used earlier. Ensure they are atTemperatureRoom temperature before proceeding.

Make sure beads are resuspended by inverting and tapping the tube. After resuspending, do not spin the beads.
At room temperature, add Amount50 µL (1 volume) of the bead suspension to each tube and mix by pipetting 10 times.

Incubate at TemperatureRoom temperature for Duration00:10:00 .

Transfer the PCR tubes containing the bead-sample mixture to the magnet and let them stand forDuration00:05:00 to completely clear the solution of beads.

Carefully remove Amount85 µL of the binding buffer and discard it. Leaving some of the volume behind minimizes bead loss at this step.

With the tubes still on the magnet, add Amount200 µL of freshly prepared 70% ethanol and allow to stand for Duration00:00:30 .

Remove the 70% ethanol wash using a pipette.
Repeat the 70% ethanol wash one more time, for a total of two washes.
With the final wash, it is critical to remove as much of the ethanol as possible. Use at least 2 pipetting steps and allow excess ethanol to collect at the bottom of the tubes after removing most of the ethanol in the first pipetting step. Try to remove last bits of ethanol with a smaller pipette.
Air dry the beads on the magnet for Duration00:10:00 . Inspect each tube carefully to ensure that all the ethanol has evaporated.

Add Amount33 µL TemperatureRoom temperature 1X low-EDTA TE buffer or Nuclease-free Water (green: D1) to the dried beads. Mix thoroughly to ensure all the beads are resuspended.
Transfer the tubes to the magnet and let them stand for Duration00:02:00 to completely clear the solution of beads.

2m
Carefully remove Amount30 µL of the eluate, ensuring as few beads as possible are carried over, then transfer to a fresh set of PCR tubes and place on ice.

Library can now be stored at Temperature-20 °C

Protocol references
Ovation RNA-Seq System V2, M01206v9, NuGEN, TECAN
Ovation Ultralow System V2, M01379v5.1, NuGEN, TECAN