1Research Unit for Precision Regenerative Medicine, Helmholtz Munich;
2Comprehensive Pneumology Center Munich (CPC-M), Member of the German Center for Lung Research (DZL);
3Department of Rheumatology and Immunology, Department of Pulmonary Medicine, Allergology and Clinical Immunology, Inselspital, Bern University Hospital, University of Bern, Bern, Switzerland;
4Lung Precision Medicine (LPM), Department for BioMedical Research (DBMR), University of Bern, Bern, Switzerland
License: This is an open access protocol distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
DISCLAIMER – FOR INFORMATIONAL PURPOSES ONLY; USE AT YOUR OWN RISK
The protocol content here is for informational purposes only and does not constitute legal, medical, clinical, or safety advice, or otherwise; content added to protocols.io is not peer reviewed and may not have undergone a formal approval of any kind. Information presented in this protocol should not substitute for independent professional judgment, advice, diagnosis, or treatment. Any action you take or refrain from taking using or relying upon the information presented here is strictly at your own risk. You agree that neither the Company nor any of the authors, contributors, administrators, or anyone else associated with protocols.io, can be held responsible for your use of the information contained in or linked to this protocol or any of our Sites/Apps and Services.
Abstract
This protocol was used to generate spatial proteomics dataset from pediatric lung, as a part of the CZI-MPII project.
Mlllex-GP Filter Unit 0.22 μm (Merck Millipore, SLGP033RS)
SDB-RPS Solid Phase Extraction Disk (Merck, 66886U)
0.2 ml PCR tubes, strip of 8, with attached caps (Eppendorf, 951010022)
0.2 ml PCR tubes, strip of 8, no cap (Thermo Scientific, AB-0452)
Compatible 0.2 ml PCR tubes caps, strip of 8 (Thermo Scientific, AB-0386)
Tissue sectioning
Tissue sectioning
Prepare consecutive FFPE tissue sections series on PEN slides and SuperFrost Plus slides according to the experiment design.
Ideally, cut all slides from the same FFPE block in one sitting (no extra trimming in between). Sections should be 10 µmthick on PEN slides for LCM, and 4 µm thick on SuperFrost Plus slides for other staining purposes. Make sure tissues are attached to the membrane area of PEN slides.
An example of the sectioning design is below (Fig. 1)
Tissue staining
Tissue staining
For the reference slides and annotation
Pick SuperFrost Plus slides adjacent to PEN slides as references. It can be stained with desired methods, e.g., H&E, AB-PAS, fluorescence, etc. This protocol continues with H&E staining as an example.
Scan the whole reference slide to generate a digital image of the full tissue.
Annotate histological regions of interest(ROIs) on the digital images. The step is essential since the ROIs may not be recognizable on LCM due to compromised resolution and dried tissue section.
For PEN slides
Pick PEN slides adjacent to the reference slides. Stain the slides with the desired methods.
Leave the slides dry in the fume hood overnight. Keep slides as clean as possible.
It is not recommended to stain PEN slides until the annotation is completed since step 4 to step 15.10 should be finished within one month to guarantee the sample quality.
Make sure all the apparatus and reagents are clean and freshly prepared to avoid contamination.
Laser capture microdissection
Laser capture microdissection
Please refer to the official manual and instructions of your LCM platform. This protocol only describes essential steps with ZEISS PALM MicroBeam as an example. A quick guide is available in the references.
Instruments Setup
Turn on the instruments, microscope, computer, and software in the correct order.
power strip
Zeiss Microscope Power Supply 232
LCM control box, turn the key to the ON position
Zeiss PALM MicroBeam
Axiovert Microscope
Computer
PALMRobo software
Mount/Unmount the slides
By choosing "Goto Load position" (Fig. 2 Button A), move the stage to the loading position. Mount the slides properly. Return the stage to the working area. Unmount the slides in the same way.
Scan the slides before and after capturing
Adjust the magnification, light intensity, display gain, white balance, and focus, to be able to observe ROIs clearly. (Fig. 3)
Choose "Navigation Window", and "Scan" tab (Fig. 4), and scan the slide in desired magnification. Save the images. Scan and save again when finish collecting ROIs from the same slide.
Mount/Unmount collection tubes
Click "Capture Device"(Fig. 2 Button C), and "Change Collector" (Fig. 5, Button A) in the pop-up window, the RoboMover will move the tube holder forward, then mount the adhesive cap tube properly. Insert the cap in the metal clip adhesive side downward. Hold the tube with the small hook.
Click "scan new collector type" or "use same collector type" (Fig. 5, small window B), the tube holder will return to the default place.
Click on the center of the blue cap (Fig. 5, Button C), the RoboMover will bring the cap to the the light path.
Draw ROIs and cut
Again, adjust the display and microscope parameters to be able to see ROIs clearly. (Fig. 3)
Click "Freehand" (Fig. 6 Button A), the mouse cursor will become a pencil, then you can draw a closed curve to select ROIs. The curve should be as close to the edge as possible. Hollow structures should be collected without the empty space.
Click "Dot" (Fig. 6 Button B), add a spot to the center or edge of the closed curve draw by freehand. It helps to detach the ROI tissue from the slides.
Click "Start laser function" (Fig. 6 Button C), the laser beam will cut the selected ROI. The detached tissue should be collected in the adhesive cap.
Click "Cap Check"(Fig. 2 Button D) to confirm the tissue is actually captured.
Experiment documentation in the Element list
Click "Element list" (Fig. 2 Button E), you will be able to see to areas of all and each element you collected.
The element list can be saved and loaded later. Together with the scanned images, it will be helpful to locate the ROIs during reviewing and thus serve as documentation of the experiment. You can also rename and recolor the elements as you wish.
Ideally should collect 600k-800k µm2 per ROI for each biological replicate.
When sufficient areas of a ROI have been collected, change the collection tube and continue with the next ROI. Refrigerate the collection tube at 4 °C until sample preparation.
When all ROIs of a slide have been collected, remove the collection tube. Scan and save again in "Navigation window" (Fig. 4).
After using the LCM platform, remove all slides and collection tubes, shut down the LCM platform in the reversed order indicated in step 5.
Sample preparation
Sample preparation
3d
3d
Please refer to the original publication in the references (Coscia et al., 2020, supplementary material and methods). Methods in this section is adapted from it and optimized for the MPII project.
Reagent Setup
Prepare all stock solutions and buffers as described in the original protocol unless certain modifications are mentioned below.
Stock solutions:
Tris/HCl 600 millimolar (mM) , 8 , in ddH2O, filter, store at Room temperature
Trifluoroacetic acid (TFA) 25 % (v/v) , in ddH2O, filter, store at Room temperature
2-chloroacetamide (CAA) 500 millimolar (mM) , in ddH2O, store at -20 °C
1,4-dithiothreitol (DTT) 100 millimolar (mM) , in ddH2O, store at -20 °C
Trypsin/Lys-C Mix 1 µg/µL , store at -80 °C
Lysis buffer
Prepare lysis buffer containing 50 % (v/v) Acetonitrile (ACN), 300 millimolar (mM) Tris-HCl(pH 8.0). I.e. Mix ACN and 600 mM Tris/HCl at 1:1 ratio.
Digestion buffer (Master mix)
10 % (v/v) TFE in ddH2O
Enzyme should be added freshly when proceed to step 15.6 at a protein:enzyme ratio of 25:1. If you add trypsin and LysC separately, keep a protein:enzyme ratio at 50:1, respectively.
Tissue homogenization and formalin de-crosslinking
Open the sample collection tube carefully since microdissected ROIs are on the adhesive cap.
Add20 µL + 20 µL lysis buffer to collect ALL COLLECTED TISSUE ROIs from the adhesive cap to a new PCR tube in 2 moves, in total volume of 40 µL.
Prepare Ref tube 1: add 40 µL ddH2O in a new PCR tube for estimation, and mark at the liquid level with a water fest lab marker.
1st Sonication
Change the water in Bioruptor and turn on mini-chiller in advance for cooling down to 4 °C
Sonicate tissue in 15 cycles in Bioruptor: high intensity, 30s on and 30s off per cycle.
Centrifuge any condensation down
De-crosslinking with a PCR machine at 65 °C overnight (12-16 hours)
The long heating period can lead to liquid loss.
Compare the liquid level of sample tubes to Ref tube 1, if necessary, adjust the volume to approximately 40 µL by adding Ultra-Pure water.
2nd Sonication
Turn on the mini-chiller in advance to cool down to 4 °C
Take PCR tubes out from the PCR machine, and spin down any condensation. Fill up the volume to 40 µL with water if necessary.
Sonicate tissue in 15 cycles in Bioruptor: high intensity, 30s on and 30s off per cycle.
Centrifuge any condensation down
Protein reduction, alkylation, and enzymatic digestion
Compare the liquid level of sample tubes to Ref tube 1, if necessary, adjust the volume to approximately 40 µL by adding Ultra-Pure water at any step.
Add 2 µLof DTT(stock concentration 100 millimolar (mM), working concentration 5 millimolar (mM)) to the sample tube.
Incubate in a ThermoMixer at 1000 rpm, 20-25°C, 00:20:00.
Spin down.
Add 2 µl of CAA(stock concentration 500 millimolar (mM), working concentration 25 millimolar (mM)) to the sample tube.
Incubate in a ThermoMixer at 1000 rpm, 20-25°C, 00:20:00.
Spin down.
Prepare Ref tube 2: add 20 µL ddH2O in a new PCR tube for estimation, and mark at the liquid level with a water fest lab marker.
Vacuum-dry the samples to a remaining volume of ca.20 µL, at 60 °C about 45 minutes.
Keep the Ref tube 2 closed. Prolong this step if necessary.
The long heating period can lead to liquid loss.
Compare the liquid level of sample tubes to Ref tube 2, if necessary, adjust the volume to approximately 20 µL by adding Ultra-Pure water.
Prepare digestion buffer Master Mix with enzyme mix.
Calculation example:
Overestimate 600k-800k µm2 ROIS can yield about 5 µg protein. The Trypsin/Lys-C Mix at 1 µg/µl should be used at a protein:enzyme ratio of 1:25. Thus, 5 µg protein requires 0.2 µg enzyme mix.
Master Mix (MM)= 1.1 *(E+B)
Volume of enzyme(E)= 1.1*(Number of samples * required enzyme (0.2 µg) * stock concentration (1 µg/µl))
Volume of Digestion buffer(B)= 1.1*(80 µl of Digestion buffer * number of samples)
For ROIs less than 400k µm2of area, recommend to use half the amount of enzyme mix, i.e. 0.1 µg per sample.
Prepare Ref tube 3: add 100 µL ddH2O in a new PCR tube for estimation, and mark at the liquid level with a water fest lab marker.
Add 80 µL freshly prepared Master Mix to each sample tube.
3rd Sonication
Turn on the mini-chiller in advance to cool down to 4 °C.
Sonicate tissue in 15 cycles in Bioruptor: high intensity, 30s on and 30s off per cycle.
Centrifuge any condensation down
Incubate in a ThermoMixer at 1000 rpm, 37°C , overnight (12-16 hours).
The long heating period can lead to liquid loss.
Compare the liquid level of sample tubes to Ref tube 3, if necessary, adjust the volume to approximately 100 µL by adding Ultra-Pure water.
Add 5 µl of TFA (stock concentration 25 % (v/v), working concentration 1 % (v/v)) to acidify the solution and inactivate the enzyme mix, Mix by pipetting and spin down for 5 mins to pellet any debris.
Here is a stop point, samples can be temporarily stored at -80 °C
Peptide Clean-up
Low pH is required for peptide clean-up by SDB-RPS StageTips
In the following steps, you can choose commercial or homemade StageTips (Rappsilber et al., 2007).
In the reference, you can find more information about the compatible tip boxes, plates, and tubes.
Prepare SDB-RPS StageTips with two layers of Solid Phase Extraction Disks(SDB-RPS).
A syringe-like tool with spring, and new boxes of P200 pipette tips without filters.
Punch the disks with the syringe tip. Inject the cut piece into the tip of a P200 pipette tip. Fix the disk with 5-6 empty injections.(Fig. 10)
Insert StageTips in the rack for holding. Label the StageTips if necessary.
Appropriately assemble the tips rack above the compatible deep-well plate, and make sure the tips are in the well (Fig. 10, 11A).Use tapes to fix the racks.
Thaw the samples. Spin down to pellet any debris prior to sample loading.
Load ca. 90 µLof samples directly on SDB-RPS StageTips, careful not to load the bottom of the sample to avoid over-loading / clogging the StageTips.
Centrifuge at 750 x g, Room temperature, 00:08:00. This step can be prolonged for 2-3 min if the liquid is not flowing through, but be careful not to leave SDB-RPS disks dry for too long.
8m
Discard the liquid in the deep-well plate.
Again, appropriately assemble the tips rack above the compatible deep-well plate, and make sure the tips are in the well (Fig. 10, 11A).Use tapes to fix the racks.
Add 200 µLof wash buffer 1 to the tip.
Centrifuge at 750 x g, Room temperature, 00:08:00.
8m
Discard the liquid in the deep-well plate.
Again, appropriately assemble the tips rack above the compatible deep-well plate, and make sure the tips are in the well (Fig. 10, 11A).Use tapes to fix the racks.
Add200 µLof wash buffer 2 to the tip.
Centrifuge at 750 x g, Room temperature, 00:08:00.
Discard the liquid in the deep-well plate.
8m
Peptide Elution
Label new capless PCR tubes for sample elution.
Insert the PCR tubes to the collection rack.
Appropriately assemble the tip rack above the compatible collection rack with capless PCR tubes. Make sure the tips are in the PCR tubes (Fig. 10, 11B).
Add 50 µLof elution buffer to the tip.
Centrifuge at 750 x g, Room temperature, 00:08:00. DO NOT discard the flow-through.
Again, add 50 µL of elution buffer to the tip.
Centrifuge at 750 x g, Room temperature, 00:08:00. DO NOT discard the flow-through.
16m
Carefully disassemble the racks and take out PCR tubes from the collection plate.
Vacuum-dry completely at 45 °C. It takes approximately 1 hour. If necessary, prolong the drying time until all samples are completely dried. A thin layer of white powder should be visible inside the PCR tube.
Close the PCR tubes with caps and seal the closed PCR tubes with parafilm.
Now the samples are ready for final preparation for mass spectrometry measurement according to experimental and instrumental setup.
Peptides can be stored at -80 °C until reconstitution for mass spectrometry measurement.
The StageTips can be kept at -20 °C until the mass spectrometry measurement result is received.
Protocol references
Coscia, F., Doll, S., Bech, J. M., Schweizer, L., Mund, A., Lengyel, E., Lindebjerg, J., Madsen, G. I., Moreira, J. M., & Mann, M. (2020). A streamlined mass spectrometry-based proteomics workflow for large-scale FFPE tissue analysis. The Journal of pathology, 251(1), 100–112. https://doi.org/10.1002/path.5420 and The supplementary materials and methods
Rappsilber, J., Mann, M., & Ishihama, Y. (2007). Protocol for micro-purification, enrichment, pre-fractionation and storage of peptides for proteomics using StageTips. Nature protocols, 2(8), 1896–1906. https://doi.org/10.1038/nprot.2007.261