Jun 02, 2022

Public workspacecDNA library preparation using ARTIC v3 primers and NEB UDI UMI adaptors for NGS V.1

  • Trevor Ho1,
  • Nahuel Manzanaro Moreno1,
  • Marion Walker1,
  • Nick Gilbert1,
  • Livia C T Scorza2
  • 1MRC Human Genetics Unit, Western General Hospital, Edinburgh EH4 2XU, UK.;
  • 2SynthSys and School of Biological Sciences, University of Edinburgh, Edinburgh, UK.
  • Trevor Ho: Developed the protocol;
  • Nahuel Manzanaro Moreno: Developed the protocol
  • Marion Walker: Developed the protocol
  • Nick Gilbert: Developed the protocol and supervised the study
  • Livia C T Scorza: Curated the protocol
Icon indicating open access to content
QR code linking to this content
Protocol CitationTrevor Ho, Nahuel Manzanaro Moreno, Marion Walker, Nick Gilbert, Livia C T Scorza 2022. cDNA library preparation using ARTIC v3 primers and NEB UDI UMI adaptors for NGS. protocols.io https://dx.doi.org/10.17504/protocols.io.3byl4b99ovo5/v1
License: This is an open access protocol distributed under the terms of the Creative Commons Attribution License,  which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Protocol status: In development
We are still developing and optimizing this protocol
Created: March 16, 2022
Last Modified: June 02, 2022
Protocol Integer ID: 59517
Keywords: SARS-CoV-2, Covid-19, wastewater, coronavirus, viral RNA, sewage
Funders Acknowledgement:
CREW (Scotland’s Centre of Expertise for Waters)
Grant ID: CD2019_06 Tracking SARS-CoV-2 via municipal wastewater
Abstract
This is a cDNA library preparation protocol with the aim to quantify SARS-CoV-2 in wastewater and potentially detect its different variants using Next Generation Sequencing (Illumina).

In this protocol, we amplified cDNA from viral RNA extracted from wastewater.

The main steps involve:

  • Amplification of cDNA with ARTIC v3 primers
  • Ligation of amplified cDNA to NEB UDI UMI adaptors
  • PCR enrichment of the libraries
  • Pooling libraries together for sequencing

The further analysis pipeline used to perform assembly and intra-host/low-frequency variant calling is the nf-core/viralrecon: https://nf-co.re/viralrecon

This protocol is still under revision
Materials
  • NEBNext® ARTIC SARS-CoV-2 Library Prep Kit (Illumina®)
  • 80% Ethanol (freshly prepared with nuclease free water)
  • Nuclease-free Water
  • DNA LoBind Tubes (Eppendorf #022431021)
  • Magnetic rack/stand (NEB #S1515, Alpaqua®, cat. #A001322 or equivalent)
  • Thermal cycler 2
  • Vortex Mixer
  • Microcentrifuge
  • Agilent® Bioanalyzer® or similar fragment analyzer and associated consumables •
  • DNase RNase free PCR strip tubes (ex. USA Scientific 1402-1708)
  • External positive control
  • Template RNA
cDNA synthesis
cDNA synthesis

AB
NTCNo-template control
EPCExternal positive control
Samplewastewater sample
It is recommended to add as templates a positive and a negative control.


For cDNA synthesis, refer to

NEBNext® ARTIC SARS-CoV-2 Library Prep Kit (Illumina®) NEB #E7650S/L Download NEB ARTIC E7650.pdfNEB ARTIC E7650.pdf

Chapter 2 Standard Protocol with cDNA Amplicon and Ligation Bead Cleanups (Three clean-up steps)

- Follow steps 2.1 to 2.3

After cDNA clean up, you can run 1 µL of the cDNA, diluted 1:10 on Agilent TapeStation with HS D1000 Tapes to look at the size distribution.

If you are confident the sizes would be correct, just use Qubit HS dsDNA protocol to quantify the input DNA amount.
Note
This cDNA quantification step is crucial for this protocol because it affects the experiment set up in subsequent procedures

Store the amplified cDNA at -20 °C.
Ligate amplified cDNA to NEB UDI UMI adaptors
Ligate amplified cDNA to NEB UDI UMI adaptors
For choosing adaptors, follow the following manual:

NEBNext® Multiplex Oligos for Illumina® - Unique Dual Index UMI Adaptors DNA Set 1
NEB #E7395S
Download NEB E7395.pdfNEB E7395.pdf

"Designed for use in library prep for DNA, ChIP DNA and RNA (but not Small RNA), the NEBNext Unique Dual Index UMI (Unique Molecular Identifier) Adaptors enable high-efficiency adaptor ligation and high library yields.
These adaptors contain all necessary sequences for sequencing on the Illumina platform, and are compatible with PCR-free applications and sample pooling prior to PCR amplification".


Refer to tables 1-4 for information on index sequences

Check Index Pooling guidelines in the manual mentioned above (NEB #E7395S )

End Prep

Follow the step 2.4 of NEBnext End Prep protocol in the NEB kit for SARS-CoV-2 detection manual (E7650)
Adaptor dilution and ligation

In this step we use parts of both protocols (E7395 and E7650)
- Adaptors with UMI are used
- A smaller reaction volume is used following that of the ARTIC kit



Adaptor dilution (optional depending on amount of input DNA)
In this step the cDNA quantification information is detrimental. Depending on the amount of DNA input, adaptor dilution is a necessary step.

"If DNA input is ≤ 100 ng, dilute NEBNext Adaptor"

Please refer to NEBNext® Ultra™ II DNA Library Prep Kit for Illumina®
NEB #E7645S/L, #E7103S/L Download NEBNext Ultra II DNA library prep for Illumina E7103-E7645.pdfNEBNext Ultra II DNA library prep for Illumina E7103-E7645.pdf

Step 2. "Adaptor Ligation - Determine whether adaptor dilution is necessary"


Adaptor ligation

Use NEBNext® Ultra™ II DNA Library Prep Kit for Illumina® NEB #E7645S/L, #E7103S/L as a guide


The E7650 protocol uses NEBNext adaptors for Illumina which are truncated and must be PCRed to add the full P5 and P7 sequences.

Those NEBNext adaptors also need the USER enzyme because the adaptors need to be cleaved prior to the PCR step.

The E7395 protocol does not require this.


Mixing together these features the ligation recipe was rewritten as follows:
COMPONENTVOLUME (µL)10.4
End Prep Reaction Mixture30-
Diluted or undiluted NEBNext UMI Adaptors for Illumina1.25-
(red) NEBNext Ultra II Ligation Master Mix15156
(red) NEBNext Ligation Enhancer0.55.2
Total Volume46.75
modified from step 2.2 of NEBNext® Ultra™ II DNA Library Prep Kit for Illumina® NEB #E7645S/L, #E7103S/L


Follow to steps 2.3 and 2.4 of the aforementioned manual (NEBNext® Ultra™ II DNA Library Prep Kit for Illumina® NEB #E7645S/L, #E7103S/L)
Samples can be stored at - 20 overnight

Cleanup of Adaptor-ligated DNA
Cleanup of Adaptor-ligated DNA
As we know most amplicons are 400 bp in size, it is not necessary to use the size selection protocol.

Rather, we move to section 3B Cleanup of Adaptor-ligated DNA without size selection for all samples

Protocol: NEBNext® Ultra™ II DNA Library Prep Kit for Illumina® NEB #E7645S/L, #E7103S/L
Note
Note:

The final volume from the last step is 46.75 µL.

It will be necessary to top it up to 93.5 µL to continue following the NEB's protocol.

*Add 46.75 µL of 0.1X TE for the top up.

*Prepare fresh 80% EtOH with nuclease-free water

Continue with cleanup according to the protocol (section 3B in Protocol for E7645)







PCR enrichment
PCR enrichment
Follow on to Step 4. PCR Enrichment of Adaptor-ligated DNA
Protocol: NEBNext® Ultra™ II DNA Library Prep Kit for Illumina® NEB #E7645S/L, #E7103S/L

Determine the number of cycles in your PCR reaction:
Note
*cDNA quantification information is important for determining the number of cycles in the PCR reaction- refer to Table 4.2.


Proceed to Step 4.1. PCR Amplification

From NEBNext® Ultra™ II DNA Library Prep Kit for Illumina® NEB #E7645S/L, #E7103S/L
PCR enriched library clean up

Follow on to Step 5 of the same manual

Checking library size distribution and library quantification
Checking library size distribution and library quantification
After clean up, run 0.5 µL of the cDNA (diluted 1:10 4.5 μL of water) on a Agilent TapeStation with HS D1000 Tapes to look at the size distribution.


We recommend running a few randomly selected libraries to confirm size distirbution.
If this the first time doing it and we see consistent aberrant patterns showing up, then it will be necessary to run all libraries to judge how widespread the issue is.
Below is an example of expected size distribution



Use a quantification method such as Qubit HS dsDNA protocol to quantify the input DNA amount.
DNA quantification here is very important
Pooling the libraries for sequencing
Pooling the libraries for sequencing
The samples that are going to be sequenced have to be pooled together in equimolar concentrations.
Note
Check the requirements of your sequencing facility

In this example we will use the requirements of the Edinburgh Genomics facility (information from 2021)
ABCDE
Sequencer typeDiluentRecommended ConcentrationMinimum ConcentrationMinimum Volume (uL)
MiSeq and NovaSeqEB-Tween>5nM*>2.5nM50 (1 lane)

*Use the following equation for nM = (ng per uL of DNA x 1,000,000) / (Number of base pairs x 660)





Example of how samples were prepared
ABCDEFGHIJ
Sample IDTotal library DNA amount (µg)Remaining volume (µL)Concentration (ng/µL)Volume ratio to reach lowest concentrationScaled volume to mix (µL)*Rounded volume (µL)DNA amount in mixed volume (ng)Mixed DNA concentration (ng/µL)Mixed DNA concentration (nM)
s0011.994229.567.60.44526627226.23372781076.23421.148
s0022.2272529.575.50.39867549675.58145695365.58421.29
s0032.0384529.569.10.43560057896.09840810426.1421.51
s0042.6579529.590.10.33407325194.67702552724.68421.668
s0052.159429.573.20.41120218585.75683060115.76421.632
s0063.36329.51140.26403508773.69649122813.7421.8
s0073.510529.51190.25294117653.54117647063.54421.26
s0080.8879529.530.111414421.4
s0091.185929.540.20.748756218910.482587064710.48421.296
s0101.191829.540.40.74504950510.430693069310.43421.372
Total volume70.54214.37659.7783829787164.6787409882
Scaled volume to mix was determined by looking at the sample with lowest concentration (s008), to which we should add 14 µL first (out of 29.5 µL)