Problem: The trigger system is not working when you check it following step 49
Problem: The Optocoupler circuit is not working or causing noise in the signal:
Solution: Check the connections. Use a soldered circuit instead of a breadboard for a more reliable connection.
Problem: The uncoated end of the electrodes was accidentally covered by dental cement.
Solution: Wait for the cement to be cured, then use a hemostat clamp to smash the covered part.
Problem: The electrode gets accidentally contaminated by contact with a non-sterile surface.
Solution: repeat the disinfection process and re-implant the electrode.
Problem: The electrode gets accidentally contaminated by contact with a non-sterile surface.
Solution: repeat the disinfection process and re-implant the electrode.
Problem: The not-railed of the time series recording.
Solution: When the signal is noisy or saturated, it may increase and sometimes fail to record at 100%, not a railed signal. If this occurs, reconnect to the board, replace the connectors for the affected channel, and check both the reference and noise-canceling pins.
Problem: Insufficient Power Supply During Recording
Solution: Before recording, ensure your AA batteries are fully charged to prevent interruptions. Check battery levels and carry spares for longer sessions.