Dec 31, 2019

Public workspaceAAV Purification by Iodixanol Gradient Ultracentrifugation V.2

  • 1Addgene
Icon indicating open access to content
QR code linking to this content
Protocol CitationAddgene The Nonprofit Plasmid Repository 2019. AAV Purification by Iodixanol Gradient Ultracentrifugation. protocols.io https://dx.doi.org/10.17504/protocols.io.bawqifdw
License: This is an open access protocol distributed under the terms of the Creative Commons Attribution License,  which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited
Protocol status: Working
We use this protocol and it's working
Created: December 31, 2019
Last Modified: December 31, 2019
Protocol Integer ID: 31408
Abstract
This protocol goes through AAV purification by Iodixanol gradient ultracentrifugation. To see the full abstract and additional resources, visit the Addgene protocol page.


Sample Data

Figure 1: Iodixanol gradient before ultracentrifugation. The steps are clearly distinguishable thanks to the use of phenol red. Image adapted from Zolotukhin, S., et al. "Recombinant adeno-associated virus purification using novel methods improves infectious titer and yield." Gene therapy 6.6 (1999): 973-985.

Figure 2:

Left panel: Iodixanol gradient after ultracentrifugation. The arrow indicates the 60-40% interface. The vertical black line indicates the location of the purified AAV. Left image adapted from Zolotukhin, S., et al. "Recombinant adeno-associated virus purification using novel methods improves infectious titer and yield." Gene therapy 6.6 (1999): 973-985 .

Right panel: cartoon indicating the position of the needle for harvesting of the purified AAV using option #1. Right image adapted by permission from Macmillan Publishers Ltd: Nature Protocols Grieger, Joshua C., Vivian W. Choi, and R. Jude Samulski. "Production and characterization of adeno-associated viral vectors," copyright (2006).

Figure 3: Example of an SDS-PAGE gel of 10 consecutive gradient fractions followed by silver stain. Note the increased number of contaminants in each fraction. * AAV capsid proteins VP1, VP2, VP3; M protein marker. Image adapted from Strobel Benjamin, Miller Felix D., Rist Wolfgang, and Lamla Thorsten. Human Gene Therapy Methods. August 2015, 26(4): 147-157. doi:10.1089/hgtb.2015.051.



Guidelines
Workflow Timeline
Day 1: Purify Day 2: Buffer exchange and concentration
Note
Note, both steps could be completed in one (long) day.

Materials
Equipment

  • Ultracentrifuge
  • T70i rotor or equivalent
Reagents
  • Opti-Prep (60% Iodixanol)
  • QuickSeal tubes
  • QuickSeal tube spacers
  • 16 ga needle
  • 18 ga needle
  • 10 mL syringe
  • 1x PBS pH 7.4
  • 1x PBS-MK buffer
  • 100X Pluronic-F68
  • NaCl
  • MgCl2
  • KCl
  • Centrifugal filter units (MWCO 100 kDa)

Reagent Preparation
1. 1 M NaCl/PBS-MK buffer
  • Dissolve Amount5.84 g of NaCl, Amount26.3 mg of MgCl2and Amount14.91 mg of KCl in 1× PBS in a final volume of Amount100 mL . Sterilize by passing through a 0.22-μm filter and store at Temperature4 °C .

2. 1x PBS-MK buffer
  • Dissolve Amount26.3 mg of MgCl2, and Amount14.91 mg of KCl in 1× PBS in a final volume of Amount100 mL . Sterilize by passing through a 0.22-μm filter and store at Temperature4 °C .

3. 0.001% Pluronic-F68 (formulation buffer)
  • Add Amount5 µL of 100X Pluronic F-68 to Amount49.95 mL of PBS. Store at Temperature4 °C for up to one month, or aliquot and store at Temperature-80 °C for up to one year.

Safety warnings
See SDS (Safety Data Sheet) for safety warnings and hazards.
Procedure
Procedure
Preparation and loading of the iodixanol gradient:
  • 15% iodixanol step: mix Amount4.5 mL of 60% iodixanol and Amount13.5 mL of 1 M NaCl/PBS-MK buffer
  • 25% iodixanol step: mix Amount5 mL of 60% iodixanol and Amount7 mL of 1x PBS-MK buffer and 30 μL of phenol red
  • 40% iodixanol step: mix Amount6.7 mL of 60% iodixanol and Amount3.3 mL of 1x PBS-MK buffer
  • 60% iodixanol step: mix Amount10 mL of 60% iodixanol and Amount45 µL of phenol red
Overlay each solution into a QuickSeal tube in the order below using a Amount10 mL syringe and an Amount18 g needle, taking care to avoid bubbles (Figure 1 sample data in abstract section).
  1. Amount5 mL of 60% iodixanol step
  2. Amount5 mL of 40% iodixanol step
  3. Amount6 mL of 25% iodixanol step
  4. Amount8 mL of 15% iodixanol step
Carefully add up to Amount5 mL of clarified supernatant on top of the gradient. Use 1x PBS (or cell lysis buffer) to top off the tube.
Seal the QuickSeal tubes.
Centrifuge at 350,000 g for Duration01:30:00 in a T70i rotor at Temperature10 °C .
Note
*Pro-Tip*
If you need more time, you can alternatively centrifuge for Duration02:00:00 at 200,000 g at Temperature18 °C .



Carefully take the QuickSeal tubes out of the rotor and place them in a stable rack.**Make sure not to disturb the gradient!**
Collect Fractions

Option #1
  • Prepare a row of roughly 20 open 1.5 mL microcentrifuge tubes in a rack. These will be used to collect fractions from the gradient. You can collect fewer fractions once you have a good idea when the virus elutes from the gradients.
  • In a biosafety cabinet, carefully puncture the QuickSeal tube at the interface of the 60% and 40% gradient (see Figure 2, in abstract section) with an 18 g needle.
  • Place the first microcentrifuge tube under the needle’s opening to collect the fractions.
  • Puncture the top of the QuickSeal tube with a 16 ga needle and start collecting Amount0.5 mL to Amount1 mL fractions per tube.
  • Avoid the proteinaceous material near the 40-25% interface.

Note
*Pro-Tip*
As soon as the top of the tube is punctured, AAV-containing Iodixanol solution will flow from the needle set at the 40-60% interface. Make sure that the microcentrifuge tubes are well positioned to collect the solution or you will lose a significant amount of your virus. When the first fraction is collected, move the rack to the next empty tube to collect the next fraction. The flow will be rapid at first and will progressively slow down.


Option #2
  • Puncture the QuickSeal tube at the bottom using an 18 g needle.
  • Immediately start collecting Amount.5 mL to Amount1 mL fractions in microcentrifuge tubes.
  • Repeat for each QuickSeal tube.
  • The first Amount8 mL collected corresponds to the 60% phase and can be discarded.
  • The fractions obtained from the 40% phase contain the purified AAV.

Option #3
  • Puncture the QuickSeal tube slightly below the 60-40% interface with an 18 g needle attached to a Amount10 mL syringe.
  • The bevel of the needle should be up, facing the 40% step.
  • Collect up to Amount5 mL per tube, taking care to avoid collecting the proteinaceous material at the 40-25% interface.
  • Repeat for each QuickSeal tube.
(Optional) For first time users, it is a good idea to assay each fraction by silver stain to determine purity. Only the cleanest fractions should be kept and pooled for dialysis.
Pool clean fractions.
Concentration and buffer exchange:

Stocks of Pluronic F68:
  • Pluronic F68, 10% solution
  • A: 0.1% in PBS: Amount49.5 mL PBS + Amount500 µL Pluronic F68
  • B: 0.01% in PBS: Amount45 mL PBS + Amount5 mL A
  • C: 0.001% in PBS: Amount45 mL PBS + Amount5 mL B + 200 mM NaCl

Procedure:
  1. Cover the filter membrane with Amount15 mL of 0.1% Pluronic F68 PBS and incubate for Duration00:10:00 at room temperature
  2. Take out the 0.1% Pluronic F68 PBS and add Amount15 mL of 0.01% Pluronic F68 PBS.
  3. Spin at 3000 RPM for Duration00:05:00 at Temperature4 °C
  4. Discard the flow through and add Amount15 mL of 0.001% Pluronic F68 + 200mM NaCl PBS.
  5. Spin at RPM rpm for Duration00:05:00 at Temperature4 °C .
  6. Discard the flow through and add your sample.
  7. Spin at 3500 RPM for Duration00:08:00 at Temperature4 °C , discard the flow through.
  8. Add more sample and spin 3500 rpm for Duration00:04:00 at Temperature4 °C , discard the flow through. Repeat this step as needed.
Note
  • Please note that iodixanol is not easily removed. After each spin, add more formulation buffer and sample and make sure to pipet back and forth a few times to mix the iodixanol that has settled at the bottom of the column.
  • We recommend concentrating to a minimum of 500 µl. If the concentrate volume is less than 500 µl, bring up the volume with formulation buffer.

9. Use a P1000 to the bottom of the filter and pipette up/down and wash off the walls of the filter to recover as much virus as possible.
Store at Temperature4 °C for short term (2 weeks), or aliquot and store at Temperature-80 °C for long term.